| 4¡¢Key technical param-
eters |
a Insulation resistance: Under the condition in which
the temperature is 25¡À10¡ãC and the humidity is less than
or equal to 80%, the insulation resistance shall be more
than or equal to 1000M¦¸
b Depth of insertion: 100-25000mm
c Outer diameter of armor: ¦Õ1-12.7
d Time constant: it shall be less than or equal to 9s
without protective tube; it shall be less than or equal
to 180s with outerside protective tube. |
| 5¡¢Key technical param-
eters of explosion-pr-
oof armoured Therm-
ocouple |
a Insulation resistance: Under the condition in which
the temperature is 25¡À10¡ãC and the humidity is less than
or equal to 80 %, The insulation resistance shall be more
than or equal to 1000M¦¸.
b Depth of insertion: 100-25000mm
c Time constant: it shall be less than less than or equal
to 9s without protective tube; it shall be less than or
equal to 180s with outer protective tube.
d Outerside diameter of armor: ¦Õ2-10
e Level of protection of outer casing: IP65, explosion-proof
mark:dIIB24, d IICT1 -6. |
6¡¢Key technical param-
eters of multipoint fla-
me-proof armored the-
rmocouple
a Insulation resistance: Under the condition
in which the temperature is 25¡À10¡ãC and the humidity is
less than or equal to 80 %, the insulation resistance
shall be more than or equal to 1000M¦¸.
b Depth of insertion: 500-30000mm
c Outerside diameter of armor: ¦Õ1.5¡«6
d Time constant:¡Ü90s
e Level of protection of outer casing: IP65, explosion-proof
mark:d IIBT1-6,
f Number of points: 3¡«12 |
7¡¢Assembling
thermocouple
¡¡¡¡As a sensor to measure and adjust the temperature,
an assembling thermocouple is generally
used to form a complete set with indicator instruments
and directly measure the temperatures of
the surface of such media as the liquid,steam and g-as
and solid in the temperature range of 0
to 1600¡ãC in various production pro-cesses.Range of temperature
measured and tolerance of
thermo-voltage of various models of thermocouples 
|
| 8¡¢Key technical parame-
ters of assembling ther-
mocouple |
a¡¢In addition to varieties of products in table above,a
Insulation resistance: Under the
condition in which the products with ZBY027-81 standard
and graduation marks of temperature is
25¡À 10¡ãC and the humidity is ¡ê80%, the EU-2, EA-2, LB-3
and LL-2 are also
supplied.insulation resistance shall be 31000MW.
b Depth of insertion: 100-2500mm
c Time constant: it shall be ¡ê90s for F16, F20 protecting
tubes; it shall be ¡ê180s for
conical protecting tube. |
| |
| |